General purpose
solenoid valves
Total separation solenoid valves (DRY)
Micro solenoid valves
Pinch solenoid valves
Components for coffee machines
Coils - Solenoids
Other products


Click on the image to enlarge it

Example: determine the pressure drop of a valve with Kv = 0,6 , air flow rate ~6,5 Nm3/h and relative upstream pressure 3 bar.

Solution: the absolute upstream pressure is P1 = 3+1 = 4 bar absolute. On the chart start from the ordinate Q, value 6,5 Nm3/h, go on horizontally until it crosses the inclined line of Kv = 0,6 go down  until it crosses the curve of the absolute upstream pressure P1 = 4 bar; and then you continue horizontally until you read the pressure drop Dp = 0,038 bar corresponding to ~ 380 mmH2O.

Q = flow rate in Nm3/h
Kv = flow factor
P1 = upstream absolute pression in bar
P2  = downstream absolute pression in bar
d   =  fluid density (air = 1)


 
Download the calculator